TBL5016-3 - 50uH 16A LISN CISPR 16-1-2
Tekbox TBL5016-3 - 50uH 16A Line Impedance Stabilisation Network LISN CISPR 16-1-2 OVERVIEW
The TBL5016-3 is a Line Impedance Stabilization Network for the measurement of line-conducted interference within the range of 9 kHz to 30MHz, according to the CISPR 16-1-2 standard.The device is designed for testing 3-phase and single-phase, AC-powered equipment with supply voltages up to a maximum 450V/260V and 16A. Conducted noise can be measured on each phase and on the neutral conductor. The TBL5016-3 has separate RF outputs for each phase and neutral and consequently can be coupled with the TBLM1 to split the emissions in its common mode and differential mode components.The single-phase DUT socket is available in country-specific variants.
Tekbox TBL5016-3 - 50uH 16A Line Impedance Stabilisation Network LISN CISPR 16-1-2 SPECIFICATIONS
- Frequency range: 9 kHz to 30 MHz
- Impedance: 50 Ω ║ (50 µH + 5 Ω)
- Artificial hand: 220 pF + 511 Ω
- Switchable PE: 50 Ω ║ 50 µH
- 250µH pre-filter
- Separate RF outputs for each line and neutral
- Air core inductors
- Line voltage: max. 540V/260V / 50 – 60 Hz, CAT ‖‖
- Max. current per line and neutral: 16A @ 23°C each
- 3-phase DUT socket: CEE/IEC60309, 3L+N+PE, 16A, female
- Single-phase DUT socket: country specific
- Power connector: CEE/IEC60309, 3L+N+PE, 16A, male
- Measurement connectors: 50 Ω BNC
- Operating Temperature Range: +5°C … + 40°C; 5% to 80% RH
- Safety: Safety Class I, IEC 1010-01
- 1980
|
|
 Updating...
Ċ Jason Lin, 2022年4月7日 晚上8:11
|